Skip to content
This repository has been archived by the owner on Feb 11, 2021. It is now read-only.

Latest commit

 

History

History
101 lines (76 loc) · 4.7 KB

README.touch

File metadata and controls

101 lines (76 loc) · 4.7 KB
 
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
===========================================================================
System Specific Notes
===========================================================================
Linux:
The linux touch system is currently based off event streams, and proc/bus/devices. The active user must be given permissions to read /dev/input/TOUCHDEVICE, where TOUCHDEVICE is the event stream for your device. Currently only Wacom tablets are supported. If you have an unsupported tablet contact me at jim.tla+sdl_touch@gmail.com and I will help you get support for it.
Mac:
The Mac and Iphone API's are pretty. If your touch device supports them then you'll be fine. If it doesn't, then there isn't much we can do.
iPhone:
Works out of box.
Windows:
Unfortunately there is no windows support as of yet. Support for Windows 7 is planned, but we currently have no way to test. If you have a Windows 7 WM_TOUCH supported device, and are willing to help test please contact me at jim.tla+sdl_touch@gmail.com
===========================================================================
Events
===========================================================================
SDL_FINGERDOWN:
Sent when a finger (or stylus) is placed on a touch device.
Fields:
event.tfinger.touchId - the Id of the touch device.
event.tfinger.fingerId - the Id of the finger which just went down.
event.tfinger.x - the x coordinate of the touch (0..touch.xres)
event.tfinger.y - the y coordinate of the touch (0..touch.yres)
event.tfinger.pressure - the pressure of the touch (0..touch.pressureres)
SDL_FINGERMOTION:
Sent when a finger (or stylus) is moved on the touch device.
Fields:
Same as FINGERDOWN but with additional:
event.tfginer.dx - change in x coordinate during this motion event.
event.tfginer.dy - change in y coordinate during this motion event.
SDL_FINGERMOTION:
Sent when a finger (or stylus) is lifted from the touch device.
Fields:
Same as FINGERDOWN.
===========================================================================
Functions
===========================================================================
SDL provides the ability to access the underlying Touch and Finger structures.
These structures should _never_ be modified.
The following functions are included from SDL_Touch.h
To get a SDL_Touch device call SDL_GetTouch(touchId).
This returns an SDL_Touch*.
IMPORTANT: If the touch has been removed, or there is no touch with the given ID, SDL_GetTouch will return null. Be sure to check for this!
An SDL_Touch has the following fields:
>xres,yres,pressures:
The resolution at which x,y, and pressure values are reported. Currently these will always be equal to 2^15, but this may not always be the case.
>pressure_max, pressure_min, x_max, x_min, y_max, y_min
Which give, respectively, the maximum and minumum values that the touch digitizer can return for pressure, x coordiniate, and y coordinate AS REPORTED BY THE OPERATING SYSTEM.
On Mac/iPhone systems _max will always be 0, and _min will always be 1.
>native_xres,native_yres,native_pressureres:
The native resolution of the touch device AS REPORTED BY THE OPERATING SYSTEM.
On Mac/iPhone systems these will always be 1.
>num_fingers:
The number of fingers currently down on the device.
>fingers:
An array of pointers to the fingers which are on the device.
The most common reason to access a touch device is to normalize inputs. This would be accomplished by code like the following:
SDL_Touch* inTouch = SDL_GetTouch(event.tfinger.touchId);
if(inTouch == NULL) continue; //The touch has been removed
float x = ((float)event.tfinger.x)/inTouch->xres;
float y = ((float)event.tfinger.y)/inTouch->yres;
To get an SDL_Finger, call SDL_GetFinger(touch,fingerId), where touch is a pointer to an SDL_Touch device, and fingerId is the id of the requested finger.
This returns an SDL_Finger*, or null if the finger does not exist, or has been removed.
An SDL_Finger is guaranteed to be persistent for the duration of a touch, but it will be de-allocated as soon as the finger is removed. This occurs when the SDL_FINGERUP event is _added_ to the event queue, and thus _before_ the FINGERUP event is polled.
As a result, be very careful to check for null return values.
An SDL_Finger has the following fields:
>x,y,pressure:
The current coordinates of the touch.
>xdelta,ydelta:
The change in position resulting from the last finger motion.
>last_x, last_y, last_pressure:
The previous coordinates of the touch.
===========================================================================
Notes
===========================================================================
For a complete example see test/testgesture.c